New Commutation Method for Current Source Inverter with Self Turn-Off Devices
-
- Kawabata Osamu
- Mitsubishi Heavy Industries, Ltd. Technical Headquarters
-
- Shinoda Hisanobu
- Mitsubishi Heavy Industries, Ltd. Technical Headquarters
-
- Shigemizu Tetsurou
- Mitsubishi Heavy Industries, Ltd. Technical Headquarters
Bibliographic Information
- Other Title
-
- 自励素子を用いる電流型電力逆変換回路の転流制御法
- ジレイソシ オ モチイル デンリュウガタ デンリョク ギャクヘンカン カイロ ノ テンリュウ セイギョホウ
Search this article
Abstract
In this paper, simplified equations were derived about relation between the commutation surge voltageand key factors of Current Source type Inverter (CSI). And the new commutation method is proposed. The new method is verified by calculations and real test. The new method can decrease the commutation surge voltage smaller half than conventional method.<br>And error between data calculated with equations derived in this paper and results of real test is smaller than 5%.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 126 (5), 659-664, 2006