New Commutation Method for Current Source Inverter with Self Turn-Off Devices

Bibliographic Information

Other Title
  • 自励素子を用いる電流型電力逆変換回路の転流制御法
  • ジレイソシ オ モチイル デンリュウガタ デンリョク ギャクヘンカン カイロ ノ テンリュウ セイギョホウ

Search this article

Abstract

In this paper, simplified equations were derived about relation between the commutation surge voltageand key factors of Current Source type Inverter (CSI). And the new commutation method is proposed. The new method is verified by calculations and real test. The new method can decrease the commutation surge voltage smaller half than conventional method.<br>And error between data calculated with equations derived in this paper and results of real test is smaller than 5%.

Journal

References(12)*help

See more

Details 詳細情報について

Report a problem

Back to top