Analytical Method for Determining Iminoctadine Triacetate by LC/ESI/MS Using Hydrophilic Interaction Chromatography

  • KAWAMOTO Tatsuhiko
    Hyogo Prefectural Institute of Public Health and Environmental Sciences
  • YANO Miho
    Hyogo Prefectural Institute of Public Health and Environmental Sciences
  • MAKIHATA Nobuko
    Hyogo Prefectural Institute of Public Health and Environmental Sciences

この論文をさがす

抄録

A target value for iminoctadine triacetate residues in tap water was set at 6 µg/l in Japan. We have developed a highly selective and sensitive analytical method for iminoctadine triacetate by solid phase extraction LC/ESI/MS using hydrophilic interaction chromatography. The recovery rates at concentration of 0.06, 0.6, and 6 µg/l in distilled water, tap water, and raw water were 77.1 - 96.7%, and CV were 3.7 - 13.2%. The quantitation limit of the present method was 0.04 µg/l, and it was able to measure even one-hundredth of the target value of iminoctadine triacetate quantitatively.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 22 (4), 489-490, 2006

    社団法人 日本分析化学会

被引用文献 (4)*注記

もっと見る

参考文献 (5)*注記

もっと見る

キーワード

詳細情報