Direct Electrodeposition of Gold Nanoparticles onto Indium Tin Oxide Film Coated Glass : Application to the Detection of Arsenic(III)

この論文にアクセスする

この論文をさがす

著者

抄録

Gold nanoparticle modified indium tin oxide (ITO) film coated glass electrodes were prepared for the first time through direct electrochemical deposition from 0.5 M H<sub>2</sub>SO<sub>4</sub> containing 0.1 mM HAuCl<sub>4</sub>. The resulting electrode surfaces were characterized with AFM. Cyclic voltammetry and linear sweep voltammetry (LSV) of arsenic(III) on the modified electrodes were performed. After optimization, a LOD of 5 ± 0.2 ppb was obtained with 60 s deposition at -0.6 V (<i>vs.</i> SCE) in 1 M HNO<sub>3</sub> using LSV.

収録刊行物

  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry  

    Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 22(4), 567-570, 2006-04-10 

    The Japan Society for Analytical Chemistry

参考文献:  30件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10018123866
  • NII書誌ID(NCID)
    AA10500785
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    09106340
  • NDL 記事登録ID
    7871978
  • NDL 雑誌分類
    ZP4(科学技術--化学・化学工業--分析化学)
  • NDL 請求記号
    Z54-F482
  • データ提供元
    CJP書誌  NDL  J-STAGE 