カソード内部加湿方式水素燃料固体高分子形燃料電池のガス供給形式による特性変化 Performance Change of Hydrogen Fueled Polymer Electrolyte Fuel Cell Internally Humidified at the Cathode by Gas Flow Pattern

この論文にアクセスする

この論文をさがす

著者

抄録

With high hydrogen utilization operation, a minor imbalance in the distributed flow of the stack causes a shortage of hydrogen gas. In order to achieve high hydrogen utilization operation, we investigated the flow pattern for cells internally humidified at the cathode side. We fabricated both counter flow and co flow type cells for humidification of the cells inside the cathode and carried out electricity generation tests on single cells and cell stacks. Also we measured the distribution of relative humidity at the anode electrode for counter flow and co flow humidification of the cell inside the cathode. From these test results we concluded that the counter flow method is superior as a humidification cell inside a cathode when using the stack division method.

収録刊行物

  • 電気学会論文誌. B, 電力・エネルギー部門誌 = The transactions of the Institute of Electrical Engineers of Japan. B, A publication of Power and Energy Society  

    電気学会論文誌. B, 電力・エネルギー部門誌 = The transactions of the Institute of Electrical Engineers of Japan. B, A publication of Power and Energy Society 126(8), 821-826, 2006-08-01 

    The Institute of Electrical Engineers of Japan

参考文献:  7件