Cooling Technology for the Optical Disc Drive using Air-flow induced by Disc Rotation

Bibliographic Information

Other Title
  • C109 ディスク回転流を利用した光ディスクドライブの冷却技術

Search this article

Abstract

Recently, data transfer rates of optical disc drives have been dramatically increasing. To obtain the high data transfer rates, disc rotation speed and laser power also need to be increased. Therefore, to develop the next generation optical disc drives effectively, enhanced cooling system of the optical pick-up unit which includes the laser diode is indispensable. The cooling performance of the pick-up unit is directly influenced by the inside airflow induced by the disc rotation. Tb maximize the effect of the airflow around the pick-up unit, we applied the combination of PIV (Particle Image Velocimetry) and CFD (Computational Fluid Dynamics) simulation. It was made clear that the tray opening near the pick-up unit increased the cooling performance effectively.

Journal

References(1)*help

See more

Details 詳細情報について

  • CRID
    1390282679594989824
  • NII Article ID
    10018247333
    130003650413
  • NII Book ID
    AA11907562
  • DOI
    10.3154/jvs.26.supplement2_145
  • ISSN
    1884037X
    09164731
  • Text Lang
    ja
  • Data Source
    • JaLC
    • Crossref
    • CiNii Articles
  • Abstract License Flag
    Disallowed

Report a problem

Back to top