磁気飽和領域における永久磁石同期機のリアクタンス評価法に関する考察 Study of Reactance Evaluation Methods in Saturated Magnetic Field for Permanent Magnet Synchronous Motor

この論文にアクセスする

この論文をさがす

著者

抄録

In order to speculate motor performance with high precision, it is important to understand correctly motor parameters, such as reactance, in an actual operation state. This paper presents a study of three reactance evaluation methods: Dalton-Cameron method, the method applying direct magnetic field and the method considering cross-magnetizing reactance. Dalton-Cameron method and the method applying direct magnetic field are superior in simplicity of measurement. But the reactance under saturated magnetic field could not be calculated correctly by two former methods, because magnetic saturation in the actual operation state is not taken into consideration. In this paper, it is indicated that the results calculated by the two former methods have errors to the measured results, and that the reactance should be calculated by the method considering cross-magnetizing reactance, when we treat the machine that has a complicated magnetic circuit.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 126(12), 1722-1729, 2006-12-01 

    The Institute of Electrical Engineers of Japan

参考文献:  5件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  1件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10018402836
  • NII書誌ID(NCID)
    AN10012320
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    09136339
  • NDL 記事登録ID
    8593329
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-1608
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ