Development of Highly Sensitive Analytical Method of Bisphenol A and Alkylphenols by High-Performance Liquid Chromatography with Large Volume Injection and Fluorometric Detection

Bibliographic Information

Other Title
  • ビスフェノールA,アルキルフェノール類の大量注入‐HPLC/蛍光検出法による高感度分析手法の開発
  • ビスフェノール A アルキルフェノールルイ ノ タイリョウ チュウニュウ HPLC ケイコウ ケンシュツホウ ニ ヨル コウカンド ブンセキ シュホウ ノ カイハツ

Search this article

Abstract

A highly sensitive analytical method for measuring bisphenol A (BPA) and 8 alkylphenols using high performance liquid chromatography (HPLC) with fluorometric detection has been developed. Detection limits improved by using both fluorometric detection and large volume injection.<BR>Sensitivities of the compounds with fluorometric detection were ca. 20 times higher than those with UV detection. And the sensitivities with large volume injection up to 400ul increased 20 times higher than those with 20μl injection.<BR>Method determination limit for BPA was 0.33 ng/m3 when sample was collected by 1l/min for 24hours. And it doesn't need preconcentration and/or derivatization techniques. This method can be applied to not only the survey of the ambient air but also indoor air. The method may be applicable to the survey of environmental water, too.

Journal

Citations (1)*help

See more

References(18)*help

See more

Details 詳細情報について

Report a problem

Back to top