インバータ駆動非接地モータの軸電圧とベアリング電流の解析 Analysis of Shaft Voltage and Bearing Current in an Inverter-Fed Nongrounded Motor

この論文にアクセスする

この論文をさがす

著者

抄録

This paper analyzes shaft voltage and bearing current in a nongrounded motor driven by a voltage-source PWM inverter. First, the shaft voltage of the nongrounded motor is measured. The experimental results indicate that a bearing current, which can not be explained by the conventional theory, exists, and that the bearing current may shorten the life of the motor bearing. To investigate the mechanism, some experiments and parameter measurements are done, and simulation models are built. As a result, it is shown that this issue is caused by unbalance in the inductance and stray capacitance of the motor windings and these resonant phenomena.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 127(3), 286-292, 2007-03-01 