顎矯正手術のコンピューターシミュレーションのための三次元情報統合システム  [in Japanese] A 3D Integration System for Computed Simulation of Orthognathic Surgery  [in Japanese]

Access this Article

Search this Article

Author(s)

    • 布留川 創 FURUKAWA HAJIME
    • 東京医科歯科大学大学院医歯学総合研究科顎顔面矯正学分野 Section of Maxillofacial Orthoganthics, Graduate School, Tokyo Medical and Dental University
    • 本橋 信義 MOTOHASHI NOBUYOSHI
    • 東京医科歯科大学大学院医歯学総合研究科顎顔面矯正学分野 Section of Maxillofacial Orthoganthics, Graduate School, Tokyo Medical and Dental University
    • 黒田 敬之 KURODA TAKAYUKI
    • 東京医科歯科大学大学院医歯学総合研究科顎顔面矯正学分野 Section of Maxillofacial Orthoganthics, Graduate School, Tokyo Medical and Dental University
    • 誉田 栄一 HONDA EIICHI
    • 東京医科歯科大学大学院医歯学総合研究科口腔放射線医学分野 Section of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University
    • 佐々木 武仁 SASAKI TAKEHITO
    • 東京医科歯科大学大学院医歯学総合研究科口腔放射線医学分野 Section of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University

Abstract

AIM: The purpose of this study is to introduce our newly developed 3D integration system for computed simulation of facial, skeletal, and occlusal changes with orthognathic surgery, and its clinical application.<BR>MATERIAL AND METHOD: The system is composed of the following three non-contact measuring units: a facial analyzer using coded pattern projection (OGIS, RFX IV), an X-ray CT machine (SIEMENS, SOMATOM PLUS S), and a dental model analyzer using laser scanning (UNISN, VMS250R). To construct common 3D coordinates, the face bow having three ceramic balls used as standard points was set on the maxillary dental arch for obtaining 3D information from each measuring unit. The 3D coordinate values were sent to the workstation (KUBOTA, Titan 2) and integrated into the common 3-D coordinate system by superposition based on the standard points of the face bow.<BR>RESULT: 1) Compared with measured values by a contact 3D measuring unit (MITSUTOYO, MXF203), the measuring reliability in the 3D distance was 1.61±0.81mm in the facial analyzer, 0.56±0.25mm in the X-ray CT machine, and 0.13±0.08mm in the dental model analyzer. 2) Measurement reliability of the predicted skeletal change based on the occlusal change was 1.20±0.36mm in the 3D distance.<BR>In clinical application, 3D skeletal and facialgraphics could be simulated based on predicted occlusal changes.<BR>CONCLUSION: 3D information from the different measuring units could be integrated with high accuracy into our 3D integration system, and its clinical applicability was satisfactorily confirmed.

Journal

  • Bulletin Of Japanese Society for Jaw Deformities  

    Bulletin Of Japanese Society for Jaw Deformities 10(3), 281-289, 2000-12-15 

    THE JAPANESE SOCIETY FOR JAW DEFORMITIES

References:  27

You must have a user ID to see the references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Cited by:  15

You must have a user ID to see the cited references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Codes

  • NII Article ID (NAID)
    10018946892
  • NII NACSIS-CAT ID (NCID)
    AN10366185
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    09167048
  • Data Source
    CJP  CJPref  J-STAGE 
Page Top