Autoradiography of Lyophilized Animal Sections: Bone Density Measurement in Osteoporosis Model Rats

Bibliographic Information

Other Title
  • オートラジオグラフィによる骨粗鬆症モデルラットの骨密度測定

Search this article

Abstract

To gain a better understanding on the β-ray radiography of lyophilized animal sections, the bone densities of the osteoporosis rats were measured using a 147Pm planar radiation source. An imaging plate as a radiation sensor was overlaid on the animal section together with a density calibrator. After exposure, radioactivity recorded on the sensor was quantified using a bio-imaging analyzer. The density calibration curve showed linearity in the wide range with a good correlation coefficient(R2≥0.999). The inter- and intra-plate variability showed CV values less than 3.7%. On the measurement of bone density, bone density differences between the sham group and ovariectomized(OVX)group were statistically significant in the femoral cortical(p=0.001)and trabecular bone(p=0.07), and vertebral trabecular bone(p=0.043). Based on these results, we developed a new and valuable method, which made it possible to measure bone density of axial skeleton of a rat, as an alternative to commonly used methods.

Journal

  • RADIOISOTOPES

    RADIOISOTOPES 57 (2), 111-119, 2008

    Japan Radioisotope Association

Citations (1)*help

See more

References(41)*help

See more

Details 詳細情報について

Report a problem