Electrochemical Analysis of Chloramphenicol Using Boron-doped Diamond Electrode Applied to a Flow-Injection System

この論文にアクセスする

この論文をさがす

著者

抄録

<p>The electrochemical properties of chloramphenicol at a boron-doped diamond thin-film (BDD) electrode were studied using cyclic voltammetry. The highest current response of chloramphenicol was obtained with phosphate buffer, pH 6 (0.1 M) in 1% ethanol. The relationship between the concentration of chloramphenicol and the current response was linear over the range of 0.1 - 10 mM (R-2 = 0.9990). The amount of chloramphenicol was analyzed by flow-injection analysis. A thin-layer flow cell equipped with a BDD electrode was used as an amperometric detector, and experiments were carried out at -0.7 V (vs. Ag/AgCl). The linear relationship between the current response and the concentration of chloramphenicol in the range of 0.1 - 50 mu M (R-2 = 0.9948) and the limit of detection of 0.03 mu M (S/N = 3) were obtained. This method has been successfully applied to the determination of chloramphenicol in sterile eye drops and milk sample by the standard addition method. The average recoveries of chloramphenicol in eye drops were 98.0%, and the average recoveries of chloramphenicol from spiked milk were 93.9 - 103%.</p>

The electrochemical properties of chloramphenicol at a boron-doped diamond thin-film (BDD) electrode were studied using cyclic voltammetry. The highest current response of chloramphenicol was obtained with phosphate buffer, pH 6 (0.1 M) in 1% ethanol. The relationship between the concentration of chloramphenicol and the current response was linear over the range of 0.1 - 10 mM (<i>R</i><sup>2</sup> = 0.9990). The amount of chloramphenicol was analyzed by flow-injection analysis. A thin-layer flow cell equipped with a BDD electrode was used as an amperometric detector, and experiments were carried out at -0.7 V (<i>vs.</i> Ag/AgCl). The linear relationship between the current response and the concentration of chloramphenicol in the range of 0.1 - 50 µM (<i>R</i><sup>2</sup> = 0.9948) and the limit of detection of 0.03 µM (<i>S/N</i> = 3) were obtained. This method has been successfully applied to the determination of chloramphenicol in sterile eye drops and milk sample by the standard addition method. The average recoveries of chloramphenicol in eye drops were 98.0%, and the average recoveries of chloramphenicol from spiked milk were 93.9 - 103%.

収録刊行物

  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry  

    Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 24(4), 493-498, 2008-04-10 

    The Japan Society for Analytical Chemistry

参考文献:  40件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10021099619
  • NII書誌ID(NCID)
    AA10500785
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    09106340
  • NDL 記事登録ID
    9452280
  • NDL 雑誌分類
    ZP4(科学技術--化学・化学工業--分析化学)
  • NDL 請求記号
    Z54-F482
  • データ提供元
    CJP書誌  NDL  IR  J-STAGE 
ページトップへ