逆流雷による配電用柱上変圧器の被害メカニズムと低圧配電線で実施する対策 Mechanism of Pole-mounted Transformer Damage by Backflow Lightning and Measures against the Damage on Low-voltage Distribution Line

この論文にアクセスする

この論文をさがす

著者

抄録

Pole-mounted transformer is one of the equipment that is easier to receive lightning damage. As our information society advances, the needs for supply reliability of electric power become higher, and the decreasing of lightning damages of pole-mounted transformers becomes necessary. In recent years, lightning protective devices (surge arresters) have been installed around the primary bushing of the transformers. Therefore, the number of disconnections around the primary bushing caused by lightning has been decreasing. However, the surge arrester that installed at the primary side of transformer cannot protect the transformer against backflow lightning that invades to the secondary side of transformer. The characteristic of the transformer damage by the backflow lightning is that electro-magnetic force occurring by the current flowing into the secondary side of transformer deforms the windings of the transformer. In this paper, the mechanism of transformer damage by the current flowing into the secondary side is clarified by the comparison between actual lightning damage case and the results of verification test using short-circuit generator. Effective counter measures against the damage of transformer by the backflow lightning are examined by EMTP calculations. From the calculation results, neutral grounding on low-voltage distribution line is the most effective measures in the point of decreasing of the amount of current flowing into the transformer. The less the grounding resistance, the less the amount of current flowing into the transformer. Moreover, decreasing the voltage of the secondary-side of the transformer is important to protect the bushing of the secondary-side. By the calculation result, it is clarified that the surge arresters installed around the secondary side of the transformer are effective for decreasing the voltage of the secondary side of the transformer.

収録刊行物

  • 電気学会論文誌. B, 電力・エネルギー部門誌 = The transactions of the Institute of Electrical Engineers of Japan. B, A publication of Power and Energy Society  

    電気学会論文誌. B, 電力・エネルギー部門誌 = The transactions of the Institute of Electrical Engineers of Japan. B, A publication of Power and Energy Society 128(6), 836-844, 2008-06-01 

    The Institute of Electrical Engineers of Japan

参考文献:  7件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  2件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10021130888
  • NII書誌ID(NCID)
    AN10136334
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    03854213
  • NDL 記事登録ID
    9531634
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-794
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ