Towards a 30kW/liter, Three-Phase Unity Power Factor Rectifier
-
- Round Simon
- ETH Zurich, Power Electronic Systems Laboratory
-
- Karutz Philipp
- ETH Zurich, Power Electronic Systems Laboratory
-
- Heldwein Marcelo
- ETH Zurich, Power Electronic Systems Laboratory
-
- Kolar Johann W.
- ETH Zurich, Power Electronic Systems Laboratory
Bibliographic Information
- Other Title
-
- Towards a 30kW/liter, three-phase unit power factor rectifier
Search this article
Abstract
In this paper, a forced air-cooled, 400kHz, 10kW Vienna Rectifier with a power density of 8.5kW/liter is presented. To further improve the power density, the switching frequency is increased to reduce the EMI filter volume. A design for an 18.5kW/liter, 2.5MHz rectifier is proposed. By using today's technology, it is calculated that the maximum power density for a forced air-cooled and water-cooled rectifier is 20.8kW/liter and 24kW/liter respectively. To achieve 30kW/liter, improvements must be made in passive component material properties, reducing semiconductor losses and improving the cooling system.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 128 (4), 481-490, 2008
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204658097024
-
- NII Article ID
- 10021134033
-
- NII Book ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL BIB ID
- 9453831
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed