Abstract
We have developed two devices applicable to evaluate genetically engineered proteins in single molecule assay: on-chip cell lysis device, and protein purification - assay device. A motor protein, F1-ATPase expressed in E.coli, was focused in this report as a target protein. Cell lysis was simply performed by applying pulse voltage between Au electrodes patterned by photolithography, and its efficiency was determined by absorptiometry. The subsequent processes, purification and assay of extracted proteins, were demonstrated in order to detect F1-ATPase and to evaluate its activity. The specific bonding between his-tag in F1-ATPase and Ni-NTA coated on a glass surface was utilized for the purification process. After immobilization of F1-ATPase, avidin-coated microspheres and adenosine tri-phosphate (ATP) solution were infused sequentially to assay the protein. Microsphere rotation was realized by activity of F1-ATPase corresponding to ATP hydrolysis. Results show that the cell lysis device, at the optimum condition, extracts enough amount of protein for single molecule assay. Once cell lysate was injected to the purification - assay device, proteins were diffused in the lateral direction in a Y-shape microchannel. The gradient of protein concentratioin provides an optimal concentration for the assay i.e. the highest density of rotating beads. Density of rotating beads is also affected by the initial concentration of protein injected to the device. The optimum concentration was achieved by our cell lysis device not by the conventional method by ultrasonic wave. Rotation speed was analyzed for several microspheres assayed in the purification - assay device, and the results were compatible to that of conventional assay in which F1-ATPase was purified in bulk scale. In conclusion, we have demonstrated on-chip cell lysis and assay appropriate for the sequential analysis without any pretreatment. On-chip devices replacing conventional bioanalytical methods will be integrated a total analysis system to evaluate engineered protein and DNA.
Journal
-
- IEEJ Transactions on Sensors and Micromachines
-
IEEJ Transactions on Sensors and Micromachines 128 (4), 167-175, 2008
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204460872704
-
- NII Article ID
- 10021135221
-
- NII Book ID
- AN1052634X
-
- ISSN
- 13475525
- 13418939
-
- NDL BIB ID
- 9452394
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed