超高温ガス炉水素製造システムの火災・爆発および化学物質に対する安全性 Safety Assessment of VHTR Hydrogen Production System against Fire, Explosion and Acute Toxicity

この論文にアクセスする

この論文をさがす

著者

抄録

  The Japan Atomic Energy Agency has been developing a nuclear hydrogen production system by using heat from the Very High Temperature Reactor (VHTR). This system will handle a large amount of combustible gas and toxic gas. The risk from fire, explosion and acute toxic exposure caused by an accident involving chemical material release in a hydrogen production system is assessed. It is important to ensure the safety of the nuclear plant, and the risks for public health should be sufficiently small. This report provides the basic policy for the safety evaluation in cases of accident involving fire, explosion and toxic material release in a hydrogen production system. Preliminary safety analysis of a commercial-sized VHTR hydrogen production system, GTHTR300C, is performed. This analysis provides us with useful information on the separation distance between a nuclear plant and a hydrogen production system and a prospect that an accident in a hydrogen production system does not significantly increase the risks of the public.<br>

収録刊行物

  • 日本原子力学会和文論文誌 = Transactions of the Atomic Energy Society of Japan  

    日本原子力学会和文論文誌 = Transactions of the Atomic Energy Society of Japan 7(3), 231-241, 2008-09-01 

    Atomic Energy Society of Japan

参考文献:  23件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10021307641
  • NII書誌ID(NCID)
    AA11643165
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    13472879
  • NDL 記事登録ID
    9629417
  • NDL 雑誌分類
    ZN36(科学技術--原子力工学・工業)
  • NDL 請求記号
    Z74-C788
  • データ提供元
    CJP書誌  NDL  J-STAGE 
ページトップへ