A Fundamental Characteristic of AC Ionic Wind Released from a Narrow Dielectric Tube with Needle-cylinder Electrode System
-
- Pothisarn Chaichan
- Department of Electrical Engineering, Faculty of Engineering, King Mongkut's Institute of Technology Ladkrabang
-
- Ohyama Ryu-ichiro
- Department of Electrical Engineering, Tokai University
この論文をさがす
抄録
A narrow ionic wind device is investigated in this experiment, in order to aim at the application to a micro electrohydrodynamic (EHD) gas pump with a needle-ring electrode system, operating without mechanical parts. The EHD pump consists of a needle electrode attached with a tapered glass tube, where the grounded ring electrode is located on outer surface. Under AC dielectric barrier discharge condition, the ionic wind is generated inside the tapered glass tube as a micro gas pump. The distribution of ionic wind velocity under AC corona discharges is analyzed by using particle image velocimetry (PIV). Ionic wind flow rate and energy efficiency are presented as a function of the corona discharge current or the electric power. The energy efficiency of ionic wind is discussed in terms of an EHD non-dimensional analysis for the corona discharge current.
収録刊行物
-
- 電気学会論文誌. A
-
電気学会論文誌. A 132 (12), 1146-1150, 2012
一般社団法人 電気学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679577116800
-
- NII論文ID
- 10031129650
-
- NII書誌ID
- AN10136312
-
- ISSN
- 13475533
- 03854205
-
- NDL書誌ID
- 024252835
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可