Application of Porous Solid Nitrogen to Space Borne Cooling Missions

この論文をさがす

抄録

A basic experiment of the sublimation heat transfer of solid cryogen has been conducted for its potential applications to cryogenic cooling of onboard instruments. The most serious concern is the separation of solid cryogen from a cooling section caused by local rapid subimation (dry-out). The condition of the dry-out initiation and the heat transfer performance in the dry-out state was especially pursued in this paper. The order of the effective thermal conductivity of porous solid nitrogen was found to be almost the same as that of pure one and far smaller than that predicted in the subimation-filtration-condensation (SFC) process. Application of the solid nitrogen to onboard cooling is also discussed.