血清分離のための血液採取管中での血清中薬物濃度変化  [in Japanese] Change in Serum Drug Concentrations in Blood Collection Tubes for Serum Separation  [in Japanese]

Abstract

Change in serum drug concentrations was examined to serum contained 27 drugs in four kinds of blood collection tube for serum separation. There was no change in serum drug concentrations for all of the test drugs in polystylene spitz (Toyokizai Co.) and clot activator tube without serum separator (CAT, Becton Dickinson Co.). On the other hand, there were significant concentration decrease (0.5ml serum, 5% decrease at 48hr) for 10 drugs, carbamazepine, carbamazepine-10, 11-epoxide, primidone, phenylethylmalonamide, phenobarbital, phenytoin, lidocaine, quinidine, cyclosporine and pentobarbital, in Vacutainer^<[○!R]> SST (SST, Becton Dickinson Co.) and 8 drugs except primidone and phenylethylmalonamide in Benoject^<[○!R]> tube (Terumo Co.) containing serum separator. The degree of the reduction in serum drug concentration in the SST was larger than that in the Benoject^<[○!R]>. The degree of the reduction in serum phenytoin and lidocaine concentrations stored at 2-8℃ was smaller than that stored at room temperature in the SST. From these results, it is found that the effect of serum separator on the serum drug concentrations varies with temperature.

Journal

Journal of the Nippon Hospital Pharmacists Association   [List of Volumes]

Journal of the Nippon Hospital Pharmacists Association 15(4), 285-291, 1989-08-20  [Table of Contents]

Japanese Society of Pharmaceutical Health Care and Sciences

Cited by:  1

You must have a user ID to see the cited references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110001798624
  • NII NACSIS-CAT ID (NCID) :
    AN00002794
  • Text Lang :
    JPN
  • Article Type :
    Journal Article
  • ISSN :
    03899098
  • Databases :
    CJPref  NII-ELS 

Export