アルカリ融解/ICP-AES による蛍光ランプ用青色蛍光体中バリウム,マグネシウム,アルミニウム及びユウロピウムの定量

書誌事項

タイトル別名
  • Quantitative Determination of Barium, Magnesium, Aluminium and Europium in Blue Phosphors for Fluorescent Lamp Using ICP-AES after Alkali Fusion

この論文をさがす

抄録

A method for the quantitative determination of barium (Ba), magnesium (Mg), aluminium (Al), and europium (Eu) in the blue phosphor for fluorescent lamps was investigated by means of an alkaline fusion method, followed by inductively coupled plasma atomic emission spectrometry (ICP-AES). About 200 mg of samples were weighed in the Pt crucibles, 3.0 g of sodium carbonate (Na2CO3) and 1.0 g of sodium tetraborate (Na2B4O7•10H2O) added, followed by the fusion. After cooling, 10-20 ml of water and 20 ml of hydrochloric acid (1 : 1) was added. The contents heated on the hot plate were dissolved. After cooling, the solutions were adjusted with water to 250 ml. Ten milliliters aliquot of solutions were diluted with water to 100 ml, sample solutions measured by ICP-AES. Working standard solutions were prepared by addition the amount of Na2CO3, Na2B4O7•10H2O and hydrochloric acid (1 : 1) as same as sample. The four calibration curves obtained from the emission intensities were linear with high correlation coefficient of more than 0.999, respectively, and a good relative standard deviations (RSD, %) of 0.69(Ba15 μg ml-1), 0.66(Mg5.0 μg ml-1), 0.84(Al30 μg ml-1), and 0.47(Eu1.0 μg ml-1). This method was successfully applied to the determination of four elements in the experimental samples.<br>

収録刊行物

被引用文献 (2)*注記

もっと見る

参考文献 (29)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘