壁面プルームの温度場について : 人為的攪乱に対する応答性  [in Japanese] On the Thermal Field of a Wall Plume : On the Responce to Artificial Disturbances  [in Japanese]

Abstract

Experimental investigations were carried out on the characteristics of the thermal field of a wall plume arising from a horizontal line heat source embedded on the low part of a vertical wall surface. For the stability analysis of the present wall plume field, a vibrating copper wire was set horizontally near the line heat source in the field. The wall plume field was disturbed by the wire, and some two-dimensional sinusoidal thermal disturbances were introduced into the wall plume field. The growth or diminution of the thermal amplitude of disturbance was measured in the wall plume field with a thermal probe. The frequency response of the disturbance in the wall plume field was also examined. As a result, it was ascertained that the frequency response of the wall plume field was fit well with the prediction of the linear stability analysis.

Journal

Transactions of the Japan Society of Mechanical Engineers. B   [List of Volumes]

Transactions of the Japan Society of Mechanical Engineers. B 64(617), 188-195, 1998-01-25  [Table of Contents]

The Japan Society of Mechanical Engineers

References:  9

You must have a user ID to see the references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Cited by:  1

You must have a user ID to see the cited references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110002396776
  • NII NACSIS-CAT ID (NCID) :
    AN00187441
  • Text Lang :
    JPN
  • Article Type :
    Journal Article
  • ISSN :
    03875016
  • NDL Article ID :
    4391018
  • NDL Source Classification :
    ZN11(科学技術--機械工学・工業)
  • NDL Call No. :
    Z16-109
  • Databases :
    CJP  CJPref  NDL  NII-ELS