This paper describes an experimental study on the effects of an initial concentration on a maximum heat transport rate of an osmotic heat pipe operated under the atmospheric pressure. The working fluid was aqueous polyethylene glycol 600 solution and the 18 tubular-type osmosis membranes made of acetyl cellulose were used. The initial concentration was varied from 0.1 to 1.0 kmol/m^3 with 0.1 kmol/m^3 step. As a result, it is shown that the optimum initial concentration exists for the maximum heat transport rate in the osmotic heat pipe. In addition, the concentrations in the solution riser and downcomer are related to the initial concentration.
Journal
- Transactions of the Japan Society of Mechanical Engineers. B [List of Volumes]
-
Transactions of the Japan Society of Mechanical Engineers. B 64(617), 254-259, 1998-01-25 [Table of Contents]