739 構造物の連結ハイブリッド振動制御  [in Japanese] Hybrid Vibration Control for Flexible Structures connected by Control Devices  [in Japanese]

Abstract

The paper proposes a hybrid connected building control method for high-rise buildings corresponding to large earthquake. The conventional vibration control method for high rise buildings is not effective to the large earthquake because of using the control force as the inertia force of the additional mass. In this hybrid control, lower modes are controlled using passive way, while higher modes are controlled by active controllers. The effective of this method is examined through simulations and experiments.