Read/Search this Article
Abstract
The thermal resistance θ_<ja> of a plastic ball grid allay (P-BGA) which mounted on a low thermal conductive printed circuit board (PCB) in a enclosure and cooled by three exhaust fans was calculated by a CFD code. A small-scale c=e model of which enclosure and cabinet had the same configuration was used as a numerical model. When nothing less than one fan was operated, the θ<ja> of c=e model was insensitive to the range of heat transfer coefficient from 0 to 5 W/(m^2K) around the cabinet. However, when none of fans was operated, θ_<ja> of the c=e model was sensitive to it. Therefore the heat transfer coefficient should be determined in advance when none of fans were operated, by using a large-scale numerical model.
Journal
- 年次大会講演論文集 : JSME annual meeting [List of Volumes]
-
年次大会講演論文集 : JSME annual meeting 2003(6), 243-244, 2003-08-05 [Table of Contents]
The Japan Society of Mechanical Engineers