Read/Search this Article
Abstract
We propose a design for a contactless power station system using meander-type coils. The coils have a pitch-interval parameter that gives the maximum induced voltage. The pitch-interval is an important parameter in coil design. The calculated result for the optimum pitch-interval provided us with a guidry principle in meander-type coil design.
Journal
- Journal of Magnetics Society of Japan [List of Volumes]
-
Journal of Magnetics Society of Japan 23(4-2), 1473-1476, 1999-04-15 [Table of Contents]
The Magnetics Society of Japan (MSJ)