標準添加法とコンピュータ計算を利用したイオン電極による鉱泉水中のフッ化物イオンの直接定量

書誌事項

タイトル別名
  • Direct determination of fluoride ion in mineral spring water with an ion-selective electrode using standard addition method and computer calculation.
  • ヒョウジュン テンカホウ ト コンピュータ ケイサン オ リヨウシタ イオン デ

この論文をさがす

抄録

In order to determine fluoride ion in mineral spring water, an ion-selective electrode method using standard addition and computer calculation was studied and compared with a conventional working curve method. The determination error due to the temperature change from 10 to 47°C was within ± 10%, while the error by the working curve method varied from +14 to -34%. The concentration change of sodium chloride in the sample greatly influenced the electrode potential, but not the recovery rate. This method also gave greater recovery rates than the working curve method even in the presence of many coexisting ions. However, aluminium ion of more than fluoride equivalent gave a negative error. In the mineral spring water containing a large quantity of salts, the recovery rate for 2 mgF/l was 102% with the RSD being 1.7% (n = 5). This technical procedure was simpler than the routine working curve method and satisfactorily accurate.

収録刊行物

  • 分析化学

    分析化学 41 (10), T125-T129, 1992

    公益社団法人 日本分析化学会

被引用文献 (1)*注記

もっと見る

参考文献 (7)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ