Dryout in a Boiling Channel under Oscillatory Flow Condition.
Search this article
Abstract
Premature dryout due to flow oscillation is a very important factor in designing boiling systems. The flow oscillation depends, in general, on system size and/or configuration, and therefore the relationship between the premature dryout and the flow oscillation has not been fully understood so far. In this investigation, a CHF experiment in a forced flow boiling channel under the oscillatory flow condition has been conducted. Numerical simulation has also been conducted based on the lumped-parameter model of the boiling channel. The simulation well represents the transient behavior of the dryout under the oscillatory flow condition.
Journal
-
- JSME International Journal Series B
-
JSME International Journal Series B 39 (2), 412-418, 1996
The Japan Society of Mechanical Engineers