Ambient air velocity distributions in and around a D.I. gasoline spray were measured using a combination of LIF and PIV techniques. A rhodamine and water solution was injected into ambient air to disperse the fine fluorescent liquid particles used as tracers. A fuel spray was injected into the fluorescent tracer cloud and was illuminated by an Nd : YAG laser light sheet (532nm). The scattered light from the spray droplets and tracers was cut off by a high-pass filter (>560nm). As the fluorescence (> 600nm) was transmitted through the high-pass filter, the tracer images were captured using a CCD camera and the ambient air velocity distribution could be obtained by PIV based on the images. This technique was applied to a D.I. gasoline spray. The ambient air flowed up around the spray and entered into the tail of the spray. Furthermore, the relative velocity between the spray and ambient air was investigated.
Journal
- JSME international journal. Ser. B, Fluids and thermal engineering [List of Volumes]
-
JSME international journal. Ser. B, Fluids and thermal engineering 46(1), 25-30, 2003-02-15 [Table of Contents]
The Japan Society of Mechanical Engineers