EMISSION PROFILE STUDIES OF CRT CATHODES

Abstract

A cathode emission proflier based on anode-hole scanning method has been developed, which reveals emission density distrlbution and local emission characteristics in a cathode surface. The 411-type impregnated cathodes with O_s-Ru coating for CRT use are studied with this emission profller having a 20 micrometer anode-hole. Several new findings have been obtained particularly in the aging processes and the oxygen gas poisoning and recovery processes, which imply the importance of emission proflle studies in understanding cathodes.

Journal

ITE Technical Report   [List of Volumes]

ITE Technical Report 21(10), 71-74, 1997-02-13  [Table of Contents]

The Institute of Image Information and Television Engineers

References:  3

You must have a user ID to see the references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.