書誌事項
- タイトル別名
-
- DURABILITY TEST METHODS FOR ROOF MEMBRANE SYSTEMS AND SOME TEST RESULTS
- メンブレン ヤネ ボウスイソウ ノ タイキュウセイ シケン ホウホウ オヨビ シケン ケッカ
この論文をさがす
抄録
What asked for durability test methods for roof membrane systems is durability of their performance, not durability of the individual materials that compose the systems. However, the most tests that have been adopted as durability tests only focus on roofing material itself. Therefore it has been difficult to estimate durability of roof membrane systems by the present test methods. In this study, new test methods to make clear performances of roof membrane systems were proposed from the idea of combining the performance tests for them described in JASS 8 with degradation conditions. The items for degradation are heat, ultraviolet irradiation, ozone and moisture. The durability of the four kinds of commercial roof membrane systems was experimentally estimated using the proposed test methods.
収録刊行物
-
- 日本建築学会技術報告集
-
日本建築学会技術報告集 7 (12), 25-29, 2001
一般社団法人 日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205173280896
-
- NII論文ID
- 110003798445
-
- NII書誌ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- NDL書誌ID
- 5640193
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可