眼底写真における血管の追跡処理による動脈の口径不同の自動検出 An Automated Method for Detecting Narrowing Arteriolar with a Focus on Irregularity in Fundus Images

    • 畑中 裕司 HATANAKA Yuji
    • 岐阜工業高等専門学校電子制御工学科 Department of Electronic Control Engineering, Gifu National College of Technology
    • 原 武史 HARA Takeshi
    • 岐阜大学大学院医学研究科再生医科学専攻再生工学講座知能イメージ情報分野 Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University
    • 周 向栄 ZHOU Xiangrong
    • 岐阜大学大学院医学研究科再生医科学専攻再生工学講座知能イメージ情報分野 Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University
    • 青山 陽 AOYAMA Akira
    • 岐阜大学大学院医学研究科眼科学教室 Department of Ophthalmology, Gifu University Graduate School of Medicine

    • 藤田 広志 FUJITA Hiroshi
    • 岐阜大学大学院医学研究科再生医科学専攻再生工学講座知能イメージ情報分野 Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University

抄録

We have developed a computer-aided diagnosis system to detect abnormalities in fundus images. In Japan, ophthalmologists usually diagnose hypertensive changes by identifying narrowing arteriolar with a focus on irregularities. The purpose of this study is to develop an automated method for detecting narrowing arteriolar with a focus on irregularities in fundus images. The blood vessel candidates were detected by the density analysis method. Next, the blood vessels to be observed for diagnosis were detected by tracking the vessel candidates extending from the optic disk. In this step, the direction of a vector was determined by the angle made by a bifurcation point and a furcation. After the connectivity of the vessel segments was adjusted based on the recognized intersections, the true tree-like structure of the retinal blood vessels was established. The abnormal blood vessels were finally detected by measuring their diameters. The comparison between the results obtained using our system and the diagnostic results of ophthalmologists showed that our proposed method automatically detected an irregularity in diameter in 75.0% of all 24 narrowing arteries with a focus on irregularities in 70 fundus images. However, approximately 2.9 normal vessel segments per image were determined to be abnormal. The automated detection of narrowing arteriolar with a focus on irregularities could help ophthalmologists in diagnosing ocular diseases.

収録刊行物

生体医工学 : 日本エム・イー学会誌   [巻号一覧]

生体医工学 : 日本エム・イー学会誌 42(4), 236-240, 2004-12-10  [この号の目次]

社団法人日本生体医工学会

参考文献:  13件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  11件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

プレビュー

プレビュー

各種コード

  • NII論文ID(NAID) :
    110004014776
  • NII書誌ID(NCID) :
    AA11633569
  • 本文言語コード :
    JPN
  • 資料種別 :
    SHO
  • ISSN :
    1347443X
  • NDL 記事登録ID :
    7255592
  • NDL 雑誌分類 :
    ZS18(科学技術--医学--医用機械・診断学・検査技術)
  • NDL 請求記号 :
    Z19-108
  • 収録DB :
    CJP書誌  CJP引用  NDL  NII-ELS