- KAWANISHI Keisuke
- Waseda University
-
- TAKESHITA Keisuke
- Waseda University
-
- AMANO Yoshiharu
- Waseda University
-
- HASHIZUME Takumi
- Waseda University
Bibliographic Information
- Other Title
-
- エジェクタつきアンモニア・水混合媒体タービンシステムの特性調査(水素製造・アンモニア利用技術,水素エネルギー技術)
Abstract
In this paper, authors propose and investigate an Ammonia-Water Mixture (AWM) turbine system with ejector. The AWM turbine system is a power cycle which is similar to a Kalina cycle. The AWM turbine system without ejector has high pressure solution which is led to the condenser through the reducing valve without using potential of the pressure. For using the pressure difference effectively, a new cycle configuration which installs ejector is proposed. The results of simulations show that the turbine system with ejector generates larger output power than that without ejector under the same condition. And the simple configuration cycle can be expected to generate almost as much output as more complicated cycle by installation of ejector.
Journal
-
- The proceedings of the JSME annual meeting
-
The proceedings of the JSME annual meeting 2004.3 (0), 273-274, 2004
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390001206062229888
-
- NII Article ID
- 110004063510
-
- ISSN
- 24331325
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed