Heat pumps using CO_2 as a natural refrigerant have been developed and are expected to contribute to energy saving in hot water supply. In residential applications, CO_2 heat pumps are used in combination with hot water storage tanks. The objective of this series of papers is to analyze the overall performance of a hot water supply system composed of a CO_2 heat pump and a hot water storage tank by numerical simulation. In the 1st report, a simulation model of a CO_2 heat pump is created based on thermodynamic equations and measured data for an existing CO_2 heat pump. In addition, the performance of a CO_2 heat pump is clarified in relation to the air temperature as well as the inlet and outlet water temperatures.
Journal
- JSME international journal. Ser. B, Fluids and thermal engineering [List of Volumes]
-
JSME international journal. Ser. B, Fluids and thermal engineering 49(2), 541-548, 2006-05-15 [Table of Contents]