The various factors which affect the investigation and the measurement result about the measuring method of temperature of freshly mixed concrete were examined. As a result, 1. When measuring time is fully able to secure, the measurement result of a bimetal thermometer, a mercury thermometer, and a digital temperature indicator is almost the same. 2. When how to deal with a thermometer is unsuitable, the measurement result of an alcohol thermometer is lower than other thermometers about 1 degree. 3. When the temperature of concrete is measured indoors, measuring time is about 1 minute irrespective of the kind of thermometer. 4. The indoor is suitable as a place which measures the temperature of concrete.