複合型インピンジ冷却構造の冷却効率分布  [in Japanese] Cooling Effectiveness Distribution of an Integrated Impingement and Pin Fin Cooling Configuration  [in Japanese]

Abstract

Experimental study was conducted for the development of the integrated impingement and pin-fin cooling configuration. The temperature measurements were performed for different test pieces with various pin and hole arrangements to clarify the cooling effectiveness variation with the pin and hole arrangements. Experiments were conducted with 673K hot gas flow and room temperature cooling air. The Reynolds number of gas side flow was 380000 and cooling air Reynolds number was 2600-40000. Test plate surface temperatures were measured by an infrared camera. A cooling effectiveness distribution on each specimen was evaluated, and compared each other. There are evidences of the existence of pins on the cooling effectiveness distributions at the exact location of those. But the cooling effectiveness distributions are independent of the hole arrangement.

Journal

Journal of the Gas Turbine Society of Japan   [List of Volumes]

Journal of the Gas Turbine Society of Japan 34(5), 363-368, 2006-09-20  [Table of Contents]

Gas Turbine Society of Japan

References:  5

You must have a user ID to see the references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110004782560
  • NII NACSIS-CAT ID (NCID) :
    AN00186926
  • Text Lang :
    JPN
  • Article Type :
    ART
  • ISSN :
    03874168
  • NDL Article ID :
    8516433
  • NDL Source Classification :
    ZN14(科学技術--機械工学・工業--熱機関)
  • NDL Call No. :
    Z16-1052
  • Databases :
    CJP  NDL  NII-ELS 

Export