Diagnosis of Thermal Efficiency of Combined Cycle Power Plants Using Optical Torque Sensors(<Special Issue>Experimental Mechanics in Heat and Fluid Flow)

    • UMEZAWA Shuichi
    • Thermal Power Technology Group. R&D Center, TOKYO ELECTRIC POWER COMPANY

Abstract

A new optical torque measurement method is proposed for diagnosis of thermal efficiency of combined cycle power plants. In the case that the plant comprises a steam turbine and a gas turbine, both of which are connected to the same generator, it is difficult to identify which turbine causes deterioration of performance when the plant efficiency is reduced. Therefore, an optical torque sensor has been developed to measure the output of each turbine, which are important data to analyze performance of each machineries in a plant. The sensor measures axial distortion caused by power transmission by use of He-Ne laser beams, small stainless steel reflectors having bar-code patterns, and a technique of signal processing featuring high frequency. It was applied to TOKYO ELECTRIC POWER COMPANY (TEPCO) commercial plants. Following system improvements, it is concluded that error factors can be eliminated and sensor performance can reach a practical use level.

Journal

JSME international journal. Ser. B, Fluids and thermal engineering   [List of Volumes]

JSME international journal. Ser. B, Fluids and thermal engineering 48(1), 129-135, 2005-02-15  [Table of Contents]

The Japan Society of Mechanical Engineers

References:  4

You must have a user ID to see the references.If you already have a user ID, please click "Login" to access the info.New users can click "Sign Up" to register for an user ID.

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110004826588
  • NII NACSIS-CAT ID (NCID) :
    AA10888815
  • Text Lang :
    ENG
  • Article Type :
    ART
  • ISSN :
    13408054
  • NDL Article ID :
    7247749
  • NDL Source Classification :
    ZN11(科学技術--機械工学・工業)
  • NDL Call No. :
    Z53-Y271
  • Databases :
    CJP  NDL  NII-ELS  J-STAGE