Development of an Integrated Impingement and Pin-Fin Cooling Structure
-
- FUKUYAMA Yoshitaka
- JAXA
-
- YAMANE Takashi
- JAXA
-
- MATSUSHITA Masahiro
- JAXA
-
- MIMURA Fujio
- JAXA
-
- NAKAMATA Chiyuki
- IHI
-
- OOKITA Youji
- IHI
-
- YOSHIDA Toyoaki
- TUAT
Bibliographic Information
- Other Title
-
- 複合型インピンジメント冷却構造体の開発
Search this article
Abstract
Experimental and numerical studies were conducted for the development of the integrated impingement and pin-fin cooling structure. In the development, the spatial arrangements of impingement hole, pin-fin and film cooling (discharge) hole were the main concern of designers. The temperature measurements were performed for different test pieces with various spatial arrangements to clarify the cooling effectiveness variation with the spatial arrangements and other cooling parameters. Moreover, conjugate numerical simulation was executed to investigate the cooling effectiveness and was evaluated by the experimental measurements.
Journal
-
- ガスタービン定期講演会講演論文集
-
ガスタービン定期講演会講演論文集 32 281-286, 2004-10-01
Gas Turbine Society of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1573105977098837888
-
- NII Article ID
- 110006173567
-
- NII Book ID
- AN10255898
-
- ISSN
- 09191941
-
- Text Lang
- ja
-
- Data Source
-
- CiNii Articles