- KITANO M.
- Biotron Institute, Kyushu University
-
- EGUCHI Hiromi
- Biotron Institute, Kyushu University
-
- MATSUI Tsuyoshi
- Biotron Institute, Kyushu University
この論文をさがす
抄録
For adequate measurement of air humidity in plant environment, characteristics of humidity sensors of ventilated psychrometer of resistance thermometers (Ps), lithium chloride relative humidity sensor (Lr), electric capacitance meter with filter (Ec), electric capacitance meter without filter (Ec-n) and absolute humidity sensor of thermistors (Ab) were examined. Static characteristics indicated that all sensors used can be applied to humidity measurement with sufficient accuracies in steady state. In dynamic characteristics, appreciable differences were found among these sensors; Ec-n was more sensitive to both absolute humidity dynamics and air temperature dynamics as compared with Ps, Lr, Ec and Ab. In particular, Lr and Ec were not able to follow to air temperature dynamics. Thus, Ec-n was estimated to be reliable for exact analysis of humidity dynamics under rapid change in air temperature, such as the vapor flux analysis, and for accurate control of air humidity.
収録刊行物
-
- BIOTRONICS
-
BIOTRONICS (13), 11-28, 1984-10
九州大学
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1573950402029849728
-
- NII論文ID
- 110006175681
-
- NII書誌ID
- AA00110208
-
- ISSN
- 02890011
-
- Web Site
- http://hdl.handle.net/2324/8111
-
- 本文言語コード
- en
-
- データソース種別
-
- CiNii Articles