1226 非接触同時測定を用いた層流予混合火炎におけるラジカル自発光強度と温度の相関(GS-6,7 噴流火炎の混合と燃焼生成物の特性,研究発表講演)

書誌事項

タイトル別名
  • 1226 Correlation between Local Temperature and Chemiluminescence by Contact-Less Simultaneously Measurements in Laminar Premixed Flames

抄録

Distributions of local flame temperature and chemiluminescence of OH*, CH* and C_2* radicals were simultaneously measured in laminar premixed flames. The temperature measurement is based on the Rayliegh scattering method. The Cassegrain optics was used to measure the chemiluminescence and Rayleigh scattering with high spatial resolution. Relationships between the local flame temperature and chemiluminescence intensities were examined. As a result, it became clear that there was a close relation between temperature and the ratio of OH* and CH* chemiluminescence intensity.

収録刊行物

詳細情報 詳細情報について

問題の指摘