- OS5-01 Cycle analysis of two-stage planar SOFC power generation by series connection of low and high temperature SOFCs
抄録
In this study, two-stage SOFC cycle by series connection of low- and high-temperature SOFCs (Lanthanum gallate and YSZ electrolyte, respectively) and a gas turbine has been studied. This cycle can extend the operating temperature range of SOFC and may increase a total power generation efficiency. This report has estimated system efficiency by cycle analysis of two-stage SOFC power generation with gas turbine. Fuel and air recirculation and external reforming have been adopted in this calculation. Physical properties and activation overpotential of low-temperature SOFC were based on recent published data and they are relatively superior to those of high-temperature SOFC. The analysis result shows the SOFC power generation efficiency of 50.3% and total power generation efficiency of 56.1% under a standard condition (low-temperature FC average temperature: 1023K, current density: 0.3A/cm^3, cell pressure: 1.0MPa, total fuel utilization ratio at PCs: 85%). The total power generating efficiency increases with increases of low-temperature SOFC average temperature and fuel and air utilization ratios, respectively. It also shows a positive cell pressure dependence, but peaks out around 1.0MPa.
収録刊行物
-
- 動力・エネルギー技術の最前線講演論文集 : シンポジウム
-
動力・エネルギー技術の最前線講演論文集 : シンポジウム 2005.10 (0), 189-190, 2005
一般社団法人 日本機械学会