Read/Search this Article
Abstract
Applying an optimal delay time reconstruction method and a point correlation dimension method to void fraction time series greatly improves the reliability of analysis. In this paper, required cross-sectional measuring points have been investigated.. We found 9-point averaging void fraction time series is sufficient for the analysis. One-point void fraction time series were also analyzed. When the air flow rate is low, all estimation results, except in the near area of a wall, passed the surrogate data test.
Journal
- 年次大会講演論文集 : JSME annual meeting [List of Volumes]
-
年次大会講演論文集 : JSME annual meeting 2005(2), 5-6, 2005-09-18 [Table of Contents]
The Japan Society of Mechanical Engineers