In order to solve global warming it is essential to realize highly efficient systems such as chemical plants or power plants including multiphase systems. In these systems, probe methods are useful for real-time and high accuracy measurements. In this study, the authors measured bubbles properties via Single-Tip Optical-fiber Probe (S-TOP). The gradient of signals obtained from the S-TOP is proportional to the interfacial velocity. We applied this relationship to bubble measurement. As a result, it is showed that the measurement for ellipsoidal shape bubble has high accuracy; the errors were less than 2%.
Journal
- 年次大会講演論文集 : JSME annual meeting [List of Volumes]
-
年次大会講演論文集 : JSME annual meeting 2005(2), 79-80, 2005-09-18 [Table of Contents]
The Japan Society of Mechanical Engineers