Read/Search this Article
Abstract
The counter-rotating type hydroelectric unit, which is composed of the tandem runners and the generator, has been proposed by the authors. The front and rear runners counter-drive the inner and the outer rotors of the generator, respectively. This unit has advantages that the rotational moment hardly acts on the casing and/or the mounting bed. This advantage is effective to utilize the mini/micro hydropower in coexisting with the natural ecosystem, because it can be easily moored with only one cable to mountain torrents and/or rivers without the civil construction on a large scale. This paper discusses the effect of the runner profiles on the performance, and presents materials of the runner design for applying this unit to various water circumstances.
Journal
- 年次大会講演論文集 : JSME annual meeting [List of Volumes]
-
年次大会講演論文集 : JSME annual meeting 2005(2), 263-264, 2005-09-18 [Table of Contents]
The Japan Society of Mechanical Engineers