Read/Search this Article
Abstract
Blade loads near the tip of cavitatig inducer in liquid nitrogen were examined with focusing on the fluid temperature. It was found that the peak of the blade load moves from the leading-edge to the trailing-edge when the cavity develops at lower cavitation number. Although the growth of the cavity length is much affected on the temperature of liquid nitrogen, the occurrence range of sub-synchronous rotating cavitation depends only on the cavity length.
Journal
- 年次大会講演論文集 : JSME annual meeting [List of Volumes]
-
年次大会講演論文集 : JSME annual meeting 2005(2), 285-286, 2005-09-18 [Table of Contents]
The Japan Society of Mechanical Engineers