434 小型集束超音波振動子における音場の可視化と圧力計測(G05-9 複雑流れ(2),G05 流体工学)  [in Japanese] 434 Visualization and Pressure Measurement of the Acoustic Field for the Small Focusing Ultrasonic Generator  [in Japanese]

Abstract

We tested two kinds of piezoelectric ceramics for small focusing ultrasonic generators. The radius of curvature of the ceramics are 8mm and 5.77mm. We measured acoustic pressure near the focus and visualized the ultrasonic field with the schlieren method. We investigated the effect of the radius of curvature on the focusing of ultrasonic wave. The result showed that better focusing is accomplished in the generator with the large radius of curvature. The experiments were simulated numerically using the finite difference method. The simulations showed the oscillating state of the edge of the ceramics affects the focusing of the ultrasonic wave.

Journal

年次大会講演論文集 : JSME annual meeting   [List of Volumes]

年次大会講演論文集 : JSME annual meeting 2005(2), 333-334, 2005-09-18  [Table of Contents]

The Japan Society of Mechanical Engineers

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110006190695
  • NII NACSIS-CAT ID (NCID) :
    AA11461871
  • Text Lang :
    JPN
  • Databases :
    NII-ELS