^<99m>Tc-ECDを用いた,脳循環予備能評価法(TIE法)の自動定量解析ツールの開発と臨床例での検証 Development and Assessment of an Automatic Quantitative Cerebral Vascular Reserve Estimation Tool for Use with Triple-injection ^<99m>Tc-ECD SPECT

    • 高木 昭浩 Takaki Akihiro
    • 大阪大学大学院医学系研究科保健学専攻医用物理工講座:富士フイルムRIファーマ株式会社(旧:第一ラジオアイソトープ研究所)臨床応用技術部 Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Osaka University:Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)
    • 吉岡 克則 Yoshioka Katsunori
    • 富士フイルムRIファーマ株式会社臨床応用技術部:第一ラジオアイソトープ研究所臨床応用技術部 Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)
    • 寺岡 悟見 Teraoka Satomi
    • 富士フイルムRIファーマ株式会社臨床応用技術部:第一ラジオアイソトープ研究所臨床応用技術部 Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)
    • 相馬 努 Souma Tsutomu
    • 大阪大学大学院医学系研究科保健学専攻医用物理工講座:富士フイルムRIファーマ株式会社(旧:第一ラジオアイソトープ研究所)臨床応用技術部 Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Osaka University:Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)

    • 河上 一公 Kawakami Kazunori
    • 富士フイルムRIファーマ株式会社(旧:第一ラジオアイソトープ研究所)臨床応用技術部 Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)
    • 村瀬 研也 Murase Kenya
    • 大阪大学大学院医学系研究科保健学専攻医用物理工講座 Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Osaka University:Clinical Application Technology Department, FUJIFILM RI Pharma Co., Ltd.(Former name: Daiichi Radioisotope Laboratories, Ltd.)

抄録

In nuclear medicine, cerebral vascular reserve(CVR) is evaluated using technetium-99m ethyl cysteinate dimer [^<99m>Tc-ECD]and acetazolamide(ACZ). We developed a protocol involving the intravenous injection of ^<99m>Tc-ECD in three divided doses(TIE method), and have found that the cerebrovascular response to ACZ depended on time after ACZ administration. However, it was difficult to obtain high-precision quantitative SPECT images by the conventional method because of complicated image processing and image degradation accompanying image subtraction. We recently developed software known as the Automatic Quantitative CVR Estimation Tool(hereinafter referred to as Triple AQCEL), which, after the input of simple parameters, enables us to carry out automatic reconstruction of quantitative SPECT images without image degradation due to subtraction. Triple AQCEL was determined to reduce image degradation caused by subtraction and to provide valid quantitative data. Because Triple AQCEL does not require manual determination of ROI or image selection for the reconstruction of quantitative SPECT images, reproducibility of regional cerebral blood flow by 3DSRT is ensured. Since all analyses in evaluation by the TIE method are automated and the operator plays no part in them, with the resulting increase of throughput, this software will contribute to improved reproducibility of regional cerebral blood flow data, and will be useful in clinical pathophysiological assessment both preoperatively and during postoperative follow-up.

収録刊行物

日本放射線技術學會雜誌   [巻号一覧]

日本放射線技術學會雜誌 63(5), 563-569, 2007-05-20  [この号の目次]

公益社団法人日本放射線技術学会

参考文献:  23件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  1件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

プレビュー

プレビュー

各種コード

  • NII論文ID(NAID) :
    110006273513
  • NII書誌ID(NCID) :
    AN00197784
  • 本文言語コード :
    JPN
  • 資料種別 :
    ART
  • ISSN :
    03694305
  • NDL 記事登録ID :
    8834094
  • NDL 雑誌分類 :
    ZS45(科学技術--医学--放射線医学)
  • NDL 請求記号 :
    Z19-205
  • 収録DB :
    CJP書誌  CJP引用  NDL  NII-ELS  J-STAGE 

書き出し