MDCTによる肝臓癌スクリーニング検査時の至適設定スライス厚の検討 Evaluation of Appropriate Slice Thickness Setting in Multidetector-row CT Examinations for Screening of Liver Cancer

    • 越田 吉郎 Koshida Kichiro
    • 金沢大学大学院医学系研究科保健学専攻 Department of Quantum Medical Technology, Kanazawa University Graduate School of Health Sciences
    • 鈴木 正行 Suzuki Masayuki
    • 金沢大学大学院医学系研究科保健学専攻 Department of Quantum Medical Technology, Kanazawa University Graduate School of Health Sciences
    • 西村 綾 Nishimura Aya
    • 金沢大学医学部附属病院放射線部 Department of Radiological Technology, Kanazawa University Hospital

    • 上野 博之 Ueno Hiroyuki
    • 金沢大学医学部保健学科放射線技術科学専攻 Department of Radiological Technology, Kanazawa University
    • 辻井 秀夫 Tsujii Hideo
    • 金沢大学医学部附属病院放射線部 Department of Radiological Technology, Kanazawa University Hospital

抄録

In this study, we evaluated clinical images to determine appropriate settings for slice thickness in screening examinations for hepatocellular carcinoma and metastatic liver cancer, which are frequently performed in abdominal CT. The clinical images of 15 cases screened for hepatocellular carcinoma and 15 cases screened for metastatic liver cancer were evaluated. The evaluation was visually performed by three abdominal radiologists, and the sensitivity and specificity of each slice thickness were calculated. Results: differences in sensitivity and specificity were not found between slice thicknesses of 2.5 mm and 5.0 mm; however, sensitivity and specificity were low, and confidence was also low at a 10.0 mm slice thickness. Furthermore, when a 5.0 mm slice thickness was adopted, it was shown that radiation dose in limited parts could be reduced greatly to a noise level that compared equally with a study in which a 2.5 mm slice thickness was adopted in another evaluation. Therefore, the objective could be achieved by using a slice thickness of about 5.0 mm in multidetector-row CT examinations for the screening of liver cancer, while controlling patient dose to a minimum.

In this study, we evaluated clinical images to determine appropriate settings for slice thickness in screening examinations for hepatocellular carcinoma and metastatic liver cancer, which are frequently performed in abdominal CT. The clinical images of 15 cases screened for hepatocellular carcinoma and 15 cases screened for metastatic liver cancer were evaluated. The evaluation was visually performed by three abdominal radiologists, and the sensitivity and specificity of each slice thickness were calculated. Results: differences in sensitivity and specificity were not found between slice thicknesses of 2.5mm and 5.0mm ; however, sensitivity and specificity were low, and confidence was also low at a 10.0mm slice thickness. Furthermore, when a 5.0mm slice thickness was adopted, it was shown that radiation dose in limited parts could be reduced greatly to a noise level that compared equally with a study in which a 2.5mm slice thickness was adopted in another evaluation. Therefore, the objective could be achieved by using a slice thickness of about 5.0mm in multidetector-row CT examinations for the screening of liver cancer, while controlling patient dose to a minimum.

収録刊行物

日本放射線技術學會雜誌   [巻号一覧]

日本放射線技術學會雜誌 64(1), 65-72, 2008-01-20  [この号の目次]

公益社団法人日本放射線技術学会

参考文献:  15件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

プレビュー

プレビュー

各種コード

  • NII論文ID(NAID) :
    110006548889
  • NII書誌ID(NCID) :
    AN00197784
  • 本文言語コード :
    JPN
  • 資料種別 :
    NOT
  • ISSN :
    03694305
  • NDL 記事登録ID :
    9353730
  • NDL 雑誌分類 :
    ZS45(科学技術--医学--放射線医学)
  • NDL 請求記号 :
    Z19-205
  • 収録DB :
    CJP書誌  NDL  NII-ELS  IR  J-STAGE