3630 東海北陸自動車道飛騨トンネルにおける換気動特性(S49-2 トンネルの空気力学と換気(2),S49 トンネルの空気力学と換気)  [in Japanese] 3630 Analysis of dynamic characteristics of the Hida Tunnel ventilation system as a part of Tokai Hokuriku Expressway  [in Japanese]

Abstract

The authors have developed a numerical simulation scheme for a selective exhaustion system. A selective exhaustion system can choose the position of the optimal concentrated exhaust port in the tunnel of facing traffic according to traffic ratio. A selective exhaustion system is effective especially in the route with big deviation in traffic ratio. The simulator is applied to the Hida Tunnel, which is under construction as a part of Tokai Hokuriku Expressway in Japan. The Hida tunnel exceeds 10km, has ventilation stations at both portals, and uses lower section as exhaustion duct, which were excavated by TBM. The calculation results show that smooth transition of damper selection could be realized, and it is shown that the current simulator is an effective tool to design such a ventilation system.

Journal

年次大会講演論文集 : JSME annual meeting   [List of Volumes]

年次大会講演論文集 : JSME annual meeting 2006(2), 353-354, 2006-09-15  [Table of Contents]

The Japan Society of Mechanical Engineers

Preview

Preview

Codes

  • NII Article ID (NAID) :
    110006634940
  • NII NACSIS-CAT ID (NCID) :
    AA11461871
  • Text Lang :
    JPN
  • Databases :
    NII-ELS