- NAKATANI Yuki
- Department of Mechanical Engineering, Doshisha University
-
- FUNAKI Jiro
- Department of Mechanical Engineering, Doshisha University
-
- HIRATA Katsuya
- Department of Mechanical Engineering, Doshisha University
Bibliographic Information
- Other Title
-
- 1524 水槽に挿入された吸込管への空気吸込(J11-5 流体連成振動(2),J11 流体関連の騒音と振動)
Abstract
Regarding the air entrainment into a suction pipe which is vertically inserted into a suction sump across a free surface, critical submergence S_c are specified concerning six parameters, such as the Froude number Fr, the Reynolds number Re, the Weber number We, back clearance X, sump breadth B and bottom clearance Z. Here, all parameters are non-dimensionalized by suction-pipe outer diameter D and suction-pipe intake velocity V_i. Consequently, the authors confirmed that the surface-tension effect is negligible at We≥20, and that the viscous effect become enough small at Re≥3.2×10^4, while Fr effect is significant. Z/D effect also becomes small at Z/D≥2.5. Most of geometric effects can be explained on the basis of the Fr-S_c/D relation.
Journal
-
- The proceedings of the JSME annual meeting
-
The proceedings of the JSME annual meeting 2007.7 (0), 113-114, 2007
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282681040009344
-
- NII Article ID
- 110007084402
-
- ISSN
- 24331325
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed