書誌事項
- タイトル別名
-
- 317 Odor Removal Characteristics of Barrier-Type Packed-Bed Nonthermal Plasma Reactor
抄録
Odor control has gained increased importance for ensuring a comfortable living environment. In this paper, the authors report the experimental results of a study of the detailed characteristics of a barrier-type packed-bed nonthermal plasma reactor used for odor control. This plasma reactor has been widely used for VOC (volatile organic compounds) decomposition and NO_x reduction. This reactor is energized by a low-cost 60Hz AC power supply. The removal efficiencies and byproduct concentrations are studied under various experimental conditions. The complete decomposition of the main odor component-NH_3-is obtained with a minimum amount of reaction byproduct formation in a dry environment. The decomposition is deteriorated by the addition of moisture. The minimum residence time is determined for the complete removal of NH_3 in the case of the packed-bed plasma reactor. Mixing another odor component such as CH_3CHO has little effect on the removal efficiency of NH_3.
収録刊行物
-
- 環境工学総合シンポジウム講演論文集
-
環境工学総合シンポジウム講演論文集 2007.17 (0), 245-246, 2007
一般社団法人 日本機械学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680813832704
-
- NII論文ID
- 110007086293
-
- ISSN
- 24242969
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可