The simple performance evaluation tools which consist of Excel spreadsheets have been used. In this paper, we apply the calculation method of partial load performance of variable-speed chiller to the tool. The method is applied without modifying the structure of the tool, and accuracy of the tool is compared with measurement performance data. Furthermore, energy consumption of centrifugal chiller for business use building in summer is calculated by the tool, and compared with results of a conventional simulation model which is high accuracy. The differences between the tool and the simulation model are from 5 to 10%.